I/P (8 Products Listed)

ControlAir T590X Series Electro Pneumatic Manifold Mount I/P Transducer for Process Control Valve Positioner
The Type-590X Manifold Mount I/P Transducer converts a variable electrical signal to a low flow proportional pneumatic output. Its compact size, light weight and immunity to shock and vibration make i...
ControlAir
ControlAir T595XP Series Electro Pneumatic Explosion-Proof I/P Transducer
The Type-595XP Explosionproof I/P (current to pressure) transducer converts a 4–20mA electrical current signal to a proportionally linear pneumatic output. The unique conversion technology utilizing o...
ControlAir
ControlAir T950XP Series Electro Pneumatic Explosion-Proof I/P Transducer
Now there's a compact I/P transducer that delivers reliable high performance for the toughest applications in the most hazardous environments: the T950XP from ControlAir. The 950XP converts an electr...
ControlAir
ControlAir I/PAC Integrated Process Air Control Electro Pneumatic Transducer
Explosion-proof field mounted I/P transducers from ControlAir are now offered as an integrated package that comes preassembled with a filter regulator and pressure gauge. Users can choose from differe...
ControlAir
ControlAir T500 Electro pneumatic Transducer (E/P)
The ControlAir Type-500X converts a current or voltage input signal to a linearly proportional pneumatic output pressure. This versatile instrument is designed for control applications that require a ...
ControlAir
ControlAir T550X Miniature I/P, E/P Electro Pneumatic Transducer
The Type-550X is an electronic pressure regulator that converts a variable signal (current or voltage) to a proportional pneumatic output. Its compact housing, accessible ports and easy adjustments pr...
ControlAir
ABB V18311H-182210100 Field mount I/P transducer, 3 to 15 PSI output
ABB's SENSYCONfield mount I/P converters are compact, rugged instruments with a unique patented signal conversion system which provides immunity to shock, vibration and mounting position. With multipl...
ABB
ABB TEIP11-PS I/P signal converter for standard signals
The TEIP11-PStherefore a connecting link between electrical/electronic andpneumatic systems. The signal conversion process is similarto the patented force balance method. Special features of the TEIP1...
ABB
 
A current to pressure; transducer (I/P) converts an analog signal (4 to 20 mA) to a proportional linear pneumatic output (3 to 15 psig). Its purpose is to translate the analog output from a control system into a precise, repeatable pressure value to control pneumatic actuators/operators, pneumatic valves, dampers, vanes, etc.

The Electro Pneumatic I/P Converter and Transducer provides a reliable, repeatable, accurate means of converting an electrical signal into pneumatic pressure in many control systems. Models of this device are usually available in direct and reverse action and are field selectable with full or split range inputs or output as the case may be.

The most common application of an Electro Pneumatic I/P Converter and Transducer is to receive an electrical signal from a controller and produce a proportional pneumatic output for operating a control valve or positioner. The device can be mounted on the wall or a pipe stand or directly on the valve actuator. Where the device can withstand vibrations, they are directly mounted on the valve actuator. In many instances, the device is remotely mounted on instrument pipe stands to reduce vibrations.


Operating Principle

The Electro Pneumatic I/P Converter and Transducer uses an electromagnetic force balance principle to change electrical signals into pneumatic signals. Typically, a 20mA input is converted into a output. 


Troubleshooting and Calibration Tips


Most Electro Pneumatic I/P Converter and Transducer are supplied instrument air of about 20psig above the required output of the device. An inoperative or poorly performing I/P transducer may just be having problem with its air supply. So to effectively troubleshoot this device, slightly open the air set drain and check that the supply air is dry and oil free. Checks can also be made on external bleed opening to verify that it is clear and free from obstruction and that it is venting properly.


This device is calibrated in much the same way as you calibrate a pressure transmitter. In calibrating the Electro Pneumatic I/P Converter and Transducer, you provide an accurate input and check the output with a test gauge or any other test device. Check Zero, Span and Linearity and adjust as necessary. You can use either an accurate current generator or an accurate voltage generator with a compulsory precision resistor of 250 ohms and half watt(1/2W) as power rating.
At Instronline we list Suppliers, Traders, Authorized Distributors, Manufacturers, Dealers in India and abroad of I/P, ControlAir T590X Series Electro Pneumatic Manifold Mount I/P Transducer for Process Control Valve Positioner, ControlAir T595XP Series Electro Pneumatic Explosion-Proof I/P Transducer, ControlAir T950XP Series Electro Pneumatic Explosion-Proof I/P Transducer, ControlAir I/PAC Integrated Process Air Control Electro Pneumatic Transducer, ControlAir T500 Electro pneumatic Transducer (E/P), ControlAir T550X Miniature I/P, E/P Electro Pneumatic Transducer, ABB V18311H-182210100 Field mount I/P transducer, 3 to 15 PSI output, ABB TEIP11-PS I/P signal converter for standard signals ,
 
We cater globally including Afghanistan, Albania, Algeria, Andorra, Angola, Antigua and Barbuda, Argentina, Armenia, Aruba, Australia Austria, Azerbaijan, Bahamas, Bahrain, Bangladesh, Barbados, Belarus, Belgium, Belize, Benin, Bhutan, Bolivia, Bosnia and Herzegovina Botswana, Brazil, Bulgaria, Burkina Faso, Burma, Burundi, Cambodia, Cameroon, Canada, Cape Verde, Central African Republic, Chad, Chile, China, Colombia, Comoros, Congo, Democratic Republic of the, Congo, Costa Rica, Cote d'Ivoire, Croatia, Cuba, Curacao, Cyprus, Czech Republic, Denmark, Djibouti, Dominica, Dominican Republic, East Timor, Ecuador, Egypt, El Salvador, Equatorial, Fiji, Finland, France Guinea, Eritrea, Estonia, Ethiopia, Fiji, Finland, France, Gabon, Gambia, The, Georgia, Germany, Ghana, Greece, Grenada, Guatemala, Guinea, Guinea-Bissau, Guyana, Haiti, Holy See, Honduras, Hong Kong, Hungary, Iceland, India, Indonesia, Iran, Iraq, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Kazakhstan, Kenya, Kiribati, Korea, North, Korea, South, Kosovo, Kuwait, Kyrgyzstan, Laos, Latvia, Lebanon, Lesotho, Liberia, Libya, Liechtenstein, Lithuania, Luxembourg, Macau, Macedonia, Madagascar, Malawi, Malaysia, Maldives, Mali, Malta, Marshall Islands, Mauritania, Mauritius, Mexico, Micronesia, Moldova, Monaco, Mongolia, Montenegro, Morocco, Mozambique, Namibia, Nauru, Nepal, Netherlands, Netherlands Antilles, New Zealand, Nicaragua, Niger, Nigeria, North Korea, Norway, Oman, Pakistan, Palau, Palestinian Territories, Panama, Papua New Guinea, Paraguay, Peru, Philippines, Poland, Portugal, Qatar, Romania, Russia, Rwanda, Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Samoa, San Marino, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Seychelles, Sierra Leone, Singapore, Sint Maarten, Slovakia, Slovenia, Solomon Islands, Somalia, South Africa, South Korea, South Sudan, Spain, Sri Lanka, Sudan, Suriname, Swaziland, Sweden, Switzerland, Syria, Taiwan, Tajikistan, Tanzania, Thailand, Timor-Leste, Togo, Tonga, Trinidad and Tobago, Tunisia, Turkey, Turkmenistan, Tuvalu, Uganda, Ukraine, United Arab Emirates, United Kingdom, Uruguay, Uzbekistan, Vanuatu, Venezuela, Vietnam, Yemen, Zambia, Zimbabwe.
 
In India we are available in Maharashtra, West Bengal, Madhya Pradesh, Tamil Nadu, Kerala, UttarPradesh, Rajasthan, Punjab, Bihar, Muzaffarpur, Haryana, Assam, Odisha, Himachal Pradesh, Uttarakhand, Jammu&Kashmir, Jharkhand, Sikkim, Namchi, Manipur, Imphal, Andamanand Nicobar, Islands, Arunachal Pradesh, Chandigarh, Chhattisgarh, Bilaspur, Dadra & Nagar Haveli, Silvassa, Delhi, Goa, Lakshadweep, Meghalaya, Mizoram , Nagaland, Puducherry, Tripura.


 

 
© Copyright 2016. All rights reserved. Instronline
×
How may we help you ?
Name*
Mobile No.
Email*
Message